1. Connect the Gemini 2 unit to the existing network through a hub, switch, router
or wireless adapter.
2. Power Gemini on. It is important that you do this only after you’ve connected
the network cable so that it can communicate with the DHCP server.
3. Make sure your computer is set to receive an IP address from DHCP. Each oper-
ating system does this in a di!erent way, so refer to your OS documentation.
4. Gemini uses NetBIOS name resolution so that you don’t need to type the IP ad-
dress into your browser. Enter http://gemini in your browser to access the web
server. The username is “admin” and the default password is blank.
5. You may optionally configure your DHCP server to assign a specific address to
Gemini so that you can always access it using the same IP address. See the
documentation for your DHCP server for details how to do this. Note: your
DCHP server is often built into your internet router.
Network without DHCP support: You may also have an existing network that does
not use a DHCP server to assign IP addresses. Such a network may be using IP auto-
configuration or static IP addresses in all of your machines.
1. Connect the Gemini 2 unit to the existing network through a hub, switch, router
or wireless adapter.
2. Power Gemini on.
3. Power your computer on, if it is not on already. Look to see what IP address is
assigned to the Ethernet port on your computer. Each OS has a di!erent way to
do this, so refer to your OS documentation. On most versions of Windows, you
can type “ipconfig” in a command prompt to see the IP address.
4. Use the hand controller menu->mount->network buttons to access Gemini’s IP
address. Uncheck the DHCP checkbox. Click on the IP address field and change
it to an IP address on the same subnet as you computer. For example, if your
computer’s IP address is 169.254.36.12, you should set Gemini’s address to
169.254.36.xxx where xxx is a number between 1 and 254 other than 12. You
should also ensure that you do not set Gemin’s IP address to be the same as any
other node on the network.
5. Gemini uses NetBIOS name resolution so that you don’t need to type the IP ad-
dress into your browser. Enter http://gemini in your browser to access the web
server. The username is “admin” and the default password is blank.
Connection with ASCOM: You can also connect through the Gemini.net ASCOM driver
to the Ethernet network port, as well as the RS232 or USB ports. The newest version of
the Gemini.net ASCOM driver now lets you use the network as a virtual serial port into
the Gemini. You can be using the Gemini.net ASCOM at the same time as accessing
the web pages of the Gemini 2, while still using any function of the web pages. The
network connection can support multiple functions at the same time.